Panel-Loc

Panel-Loc™ is a low rib (5/8”) panel that is best used for post frame barns and buildings, as well as residential roofing. Panel-Loc™ is available in 26 and 29 gauge steel.

General Information
- Panel Rib Height: 5/8″
- Panel Coverage: 36″ wide
- Panel Length: 26″ to 45′ in .5″ increments
- Tensile Strength: 80,000 psi minimum
- Substrate: Varies by option; Galvalume (AZ-50) or Galvanized (G90)
- Gauge: 26 and 29
- Recommended Roof Slope: 3:12 pitch minimum
Testing and Approval Data
- Fire resistance: UL790/Class A
- Impact Resistance: UL2218/Class 4-Prime and Select Material
- Uplift Resistance: not available
- Construction numbers: not available
- Load Tables: Panel-Loc Load Table
- Regional Certifications: not available
Related Files
- Product Flyer: Panel-Loc Flyer
- Color Charts: 2011 Low Rib CentralGuard Color Chart; 2011 Thrifty Color Chart
- Product Guide: Light Gauge Product Guide
- Trim and Accessories: Light Gauge Trim and Accessories
- Installation Guidelines: Low Rib Installation Guidelines; DripX Installation Preparation
- Warranties: Link to Warranties
- Other: DripX Flyer
Available Options
| Thrifty | Prime | Kynar | |
|---|---|---|---|
| MCA Certification | #229SPL | #229PPL | |
| 26 Gauge Thickness | .018″ nom | .0185″ min | N/A |
| 29 Gauge Thickness | .0142″ nom | .015″ min | .015″ min |
| Tensile Strength | 80,000 psi minimum | 80,000 psi minimum | 80,000 psi minimum |
| Substrate | Varies | Galvalume | Galvalume |
| Gauge | 26 and 29 | 26 and 29 | 29 only |
| Coating | CentralGuard | CentralGuard | Fluropon (Kynar 500/Hylar 5000) |
| Primer | .1-.2 mils top | .2-.3 mils top | .2-.3 mils top |
| Paint Thickness | .5-.6 mils top | .7-.8 mils top | .7-.8 mils top |
| Warranty | 10 yr. Paint Integrity | 40 Yr. Paint and 20 Yr. Galvalume Substrate | 40 Yr. Paint and 20 Yr. Galvalume Substrate |
| Colors | 10 | 19 | 1 – Copper Metallic Only |