facebook_pixel

QUALITY CHECKS

Research and Testing

Our products have been rigorously tested to make sure that they meet the highest standards of quality. We seek to meet or exceed the industry standards by focusing on our 520 quality control checks to ensure a consistent, reliable product. The chart below summarizes the testing and approvals that are available on each product. In some cases, products are licensed, and testing will be available in licensor’s name.

TESTINGDESCRIPTION
TAS 100-95Wind Driven Rain Test
TAS 125-03Uplift Resistance Test, 29 gauge
UL580Uplift Resistance Test, 29 gauge
ASTM-E455Diaphragm Shear Standard Test, 26 gauge
ASTM-E455Diaphragm Shear Standard Test, 29 gauge
APPROVALSDESCRIPTION
UL2218UL Approval, Impact Resistance
UL580UL Approval, Uplift Resistance
UL790UL Approval, Fire Resistance, Class A
RC-325Texas Windstorm Approval, 29 gauge over wood purlins
RC-326Texas Windstorm Approval, 29 gauge over decking
FL14026.2Florida Approval, Roof Panel over 15/32" Plywood (HVHZ, Miami-Dade approved)
FL14026.3Florida Approval, Roof Panel over 15/32" Plywood (NON-HVHZ)
FL14026.4Florida Approval, Panel over 2X4's. (NON-HVHZ)
TESTINGDESCRIPTION
AISI S907Diaphragm Shear Cantilever Test, 26 gauge
ASTM-E455Diaphragm Shear Standard Test, 26 gauge
ASTM-E1592Structural Test for Roof Systems over Open Purlin, 26 gauge
ASTM-E1592Structural Test for Roof Systems over Solid Decking, 26 gauge
ASTM-E1646Water Leakage Test of exterior metal roof panel, 26 gauge
FM4471Foot Traffic Resistance Test

APPROVALSDESCRIPTION
UL2218 UL Approval, Impact Resistance
UL580UL Approval, Uplift Resistance
UL790UL Approval, Fire Resistance, Class A
FL14024.1Florida Approval, Wall Panel over Open Framing (NON-HVHZ)
FL14016.3Florida Approval, Roof Panel over Open Framing (NON-HVHZ)
RC-424Texas Windstorm Approval, 26 gauge over steel purlins
TESTINGDESCRIPTION
UL580Uplift Resistance Test, 26 gauge
UL2218Impact Resistance Test, 26 gauge

APPROVALSDESCRIPTION
UL2218UL Approval, Impact Resistance (Metal Forming Test)
UL790UL Approval, Fire Resistance, Class A
FL14026.1Florida Approval, Roof Panel over Solid Decking (NON-HVHZ)
RC-423Texas Windstorm Approval, 26 gauge over 1/2” thick plywood
APPROVALSDESCRIPTION
UL2218UL Approval, Impact Resistance
UL580UL Approval, Uplift Resistance
UL790UL Approval, Fire Resistance, Class A
APPROVALSDESCRIPTION
UL2218UL Approval, Impact Resistance
UL580UL Approval, Uplift Resistance
UL790UL Approval, Fire Resistance, Class A
RC-445Texas Windstorm Approval, 26 gauge over steel purlins
APPROVALSDESCRIPTION
RC-150Texas Windstorm Approval, 29 gauge over 19/32" thick plywood
APPROVALSDESCRIPTION
UL2218UL Approval, Impact Resistance
UL790UL Approval, Fire Resistance, Class A
TESTINGDESCRIPTION
ASTM-E1592.1Structural Test for Roof Systems, 24 gauge
ASTM-E1680Air Leakage Test through exterior metal roof panel
ASTM-E1646Water Leakage Test of exterior metal roof panel
FM4471Foot Traffic Resistance Test (MBCI Licensed Test)

APPROVALSDESCRIPTION
UL2218UL Approval, Impact Resistance
UL580UL Approval, Uplift Resistance
UL790UL Approval, Fire Resistance, Class A
FL14016.1Florida Approval, 24 gauge roof panel over open framing (NON-HVHZ)
RC-448Texas Windstorm Approval, 24 gauge, with wind clamps, over steel purlins
RC-449Texas Windstorm Approval, 24 gauge over steel purlins
TESTINGDESCRIPTION
ASTM-E1680Air Leakage Test through exterior metal roof panel (MBCI Licensed Test)
ASTM-E1646Water Leakage Test of exterior metal roof panel (MBCI Licensed Test)

APPROVALSDESCRIPTION
UL2218UL Approval, Impact Resistance
UL580UL Approval, Uplift Resistance
UL790UL Approval, Fire Resistance, Class A
FL14016.2Florida Approval, 24 gauge roof panel over open framing (NON-HVHZ)
TESTINGDESCRIPTION
FM4471Foot Traffic Resistance Test (BRS Licensed Test)
ASTM-E1680Air Leakage Test through exterior metal roof panel
ASTM-E1646Water Leakage Test of exterior metal roof panel
ASTM-E1592Structural Test for Roof Systems, 24 gauge
ASTM-E2140Water penetration by static water pressure head

APPROVALSDESCRIPTION
UL2218UL Approval, Impact Resistance
UL580UL Approval, Uplift Resistance
UL790UL Approval, Fire Resistance, Class A
RC-446Texas Windstorm Approval, 24 gauge quad lock, over steel purlins
RC-447Texas Windstorm Approval, 24 gauge triple lock, over steel purlins
TESTINGDESCRIPTION
ASTM-E1680Air Leakage Test through exterior metal roof panel
ASTM-E1646Water Leakage Test of exterior metal roof panel
UL580UL Approval, Uplift Resistance

APPROVALSDESCRIPTION
UL2218UL Approval, Impact Resistance
UL580UL Approval, Uplift Resistance
UL790UL Approval, Fire Resistance, Class A
FL17566.1Florida Approval, Roof Panel over 15/32" Plywood (NON-HVHZ)
RC-444Texas Windstorm Approval, 24 gauge over plywood decking